ISSN : 2146-3123
E-ISSN : 2146-3131

A Multimodular AI Algorithm for Automated Assessment of Left Ventricular Function in Ischemic Heart Disease: Ejection Fraction, Wall Motion, and Regional Myocardial Segmentation
Sidem Gül1, Reşit Taşdemir2, Beyza Açıkgöz2, Hakan Duman3, Hamza Hodzic4, Sena Köker5, Nazlı Erdemir6, Mehmet Kıvrak7
1Department of Medicine, Recep Tayyip Erdoğan University Faculty of Medicine, Rize, Türkiye
2Department of Software Engineering, Malatya Turgut Özal University Faculty of Engineering and Natural Sciences, Malatya, Türkiye
3Department of Cardiology, Recep Tayyip Erdoğan University Faculty of Medicine, Rize, Türkiye
4Turkish Red Crescent Blood Donation Center, Kastamonu, Türkiye
5Department of Medicine İstanbul University Faculty of Medicine, İstanbul, Türkiye
6Department of Biomedical Engineering, Kocaeli University Faculty of Technology, Kocaeli, Türkiye
7Department of Biostatistics and Medical Infıormatics, Recep Tayyip Erdoğan University Faculty of Medicine, Rize, Türkiye
DOI : 10.4274/balkanmedj.galenos.2025.2025-8-160

Abstract

Background: Ischemic heart damage reduces the pumping efficiency of the heart by affecting the left ventricular ejection fraction (LVEF) and causing wall motion abnormality (WMA). In daily clinical practice, these parameters are interpreted by physicians using two dimensional transthoracic echocardiography (2D-TTE). Because 2D TTE reports rely on visual evaluations, they are subject to experience-based limitations and exhibit low reproducibility.

Aims: To develop an artificial intelligence algorithm composed of two modules that enable automatic LVEF calculation and WMA detection for analyzing 2D-TTE images.

Study Design: Diagnostic accuracy study.

Methods: A total of 600 adult patients were retrospectively included. The model combined static frame segmentation with dynamic tracking using a hybrid Simpson’s method applied to apical 2- and 4-chamber views. Model performance was assessed against cardiologist measurements using Bland-Altman analysis. The YOLOv8 and ResNet50 models were employed for the wall motion module. Performance metrics, including accuracy, precision, F1 score, and area under the curve, were evaluated.

Results: In the Bland-Altman analysis, the mean bias between the LVEF module and cardiologist measurements was -4, with limits of agreement ranging from -15 to -3. Regression analysis demonstrated a strong correlation between the LVEF module and cardiologist measurements (r = 0.71, p < 0.001). In the wall motion module, the YOLOv8 segmentation model exhibited high accuracy, while ResNet50 achieved superior performance with an accuracy of 95%. The algorithm’s color coding contributed to standardized interpretation among operators, enhancing consistency.

Conclusion: This is the first study to integrate automated EF calculation and WMA detection within a single workflow. SafeHeart offers accurate, reproducible, and rapid analysis, with the potential to support routine echocardiography practice. Color-coded region segmentation can facilitate more standardized and reliable results.

Viewed : 26